Application:
The GU INSIDE DROP INLET serves to overcome elevation differences
between an incoming wastewater connection and the manhole base.
This device reduces wastewater inflow energy and lessens turbulent
entry into main channel flow, will reduce H2S emissions, odor and
subsequent erosion / corrosion of manhole structure.
Design:
Incorporates mounting flange and gasket to mount against the inside
radius of the manhole riser. Available is an optional corrosion
resistant F.R.P. Adaptor used with Rubber Boot Seal mounting for
cored hole in Lined Concrete Barrel Riser and PVC / F.R.P. Pipe
Riser Manhole.
TYPE 300 - Suitable for mounting in manholes, 42"*, 48" and
54"* Dia.
TYPE 370 - Suitable for mounting in manholes, 48", 54"* and
60" Dia.
*42" and 54" Diameter Manhole typical of insertion type Rehab Manhole
Liner Systems
Construction:
Molded
Polyethylene.
Gasket:
"O" ring design of polyisoprene 40-45 Durometer, approximately
1" diameter.
Mounting:
Precast Concrete / Masonry Manhole: The GU INSIDE DROP INLET
may be bolted to interior of manhole wall using four 3/8" dia. stainless
steel wedge anchors or threaded stainless steel rod / epoxy bonded
anchors PVC / F.R.P. Pipe Riser Manhole: The GU INSIDE DROP INLET
is to be installed in a cored hole with the GU PIPE RISER BOOT
SLEEVE ADAPTOR used to seat the "jack in place" flexible connector
(rubber boot). The GU INSIDE DROP INLET may then be secured
to interior of pipe riser using with four 3/8" dia. stainless steel
bolt, nut and fender washer assemblies. Important note for precast
concrete structures with integral liners or PVC / F.R.P. pipe riser
manholes: All mechanical anchor attachments through liner surfaces
or pipe riser must be sealed with an elastomeric sealant approved
by the "liner manufacturer".
Inlet
Connection:
Type 300 - Will accept either 4" 6" or 8" incoming
line connected with flexible connectors (boot). Maximum
diameter of cored hole is 12.1". It is recommended that an 8" cored
hole be used for "jack in place" flexible connectors (rubber boots)
on 4" inlets and a 12.1" cored hole be used for "jack in place"
flexible connectors (rubber boots) on 6" and 8" inlets.
Type 370 -Will accept 6", 8", or 10" incoming line
connected with flexible connectors (boot). Maximum diameter of cored
hole is 14.5". It is recommended that a 10" or 12'' cored hole be
used "jack in place" flexible connectors (rubber boots) on 6" and
8" inlets and a 14" cored be used for "jack in place" flexible connectors
(rubber boots) on 10" inlets.
Drop
Pipe Connection:
Will accept bell and gasket end of 6" or 8" PVC SDR26 / SDR35 gravity
sewer pipe and elbow as the vertical conduit inside the manhole
structure to direct flow into manhole base main channel.
Cleanout
/ Inspection Cap: Threaded type, which may be
modified to serve as a half dam by cutting out a "half - moon" shaped
opening in upper half of the cap center. Take care not to damage
cap threads. A stainless steel cable or chain may also be attached
to cap and to one of the threaded wedge anchors to prevent accidental
loss after installation. Note: Drop pipe, stainless steel wedge
anchors / bolts, threaded stainless steel rod, epoxy anchor bond
material, stainless steel cable / chain clamps, saddles, and elbows,
to be supplied by others.
|